Silex-technology Embedded Intelligent Module SX-560 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Silex-technology Embedded Intelligent Module SX-560. Silex technology Embedded Intelligent Module SX-560 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 110
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Developer’s Reference Guide

SX-560 Embedded Intelligent Module Developer’s Reference Guide

Strona 2

Page 4 silex Introduction Part Number 140-00192-100

Strona 3 - Contents

Page 94 Silex Engineering Drawings Part Number 140-00192-100

Strona 4 - Page ii

Firmware Update Procedures Silex Page 95 Part Number 140-00192-100 Appendix D Firmware Update Procedures Occasionally it may be necessary to update

Strona 5 - Figures

Page 96 Silex Firmware Update Procedures Part Number 140-00192-100 where ipaddress is the IP address of the SX-560, and filename is the file name (an

Strona 6 - Page iv

SVL USB Firmware Silex Page 97 Part Number 140-00192-100 Appendix E Using the Silex Virtual Link USB Software The SX-560 can be used to connect USB

Strona 7 - About This Reference Guide

Page 98 Silex SVL USB Firmware Part Number 140-00192-100

Strona 8 - Page 2

GNU/Linux Programming Silex Page 99 Part Number 140-00192-100 Appendix F GNU/Linux Open Source and Programming The SX-560 is designed around GNU/Lin

Strona 9 - Chapter 1: Introduction

Page 100 Silex GNU/Linux Programming Part Number 140-00192-100

Strona 10 - Part Number 140-00192-100

Silex Contact Information Silex Page 101 Part Number 140-00192-100 Appendix G Silex Contact Information Silex Technology America, Inc. www.silexame

Strona 11 - Chapter 2

Page 102 Silex Silex Contact Information Part Number 140-00192-100

Strona 12 - Page 6

Part Number 140-00192-100 Revision C-2

Strona 13 - Page 7

Installing the Evaluation Daughtercard Silex Page 5 Part Number140-00192-100 Chapter 2 Installing the Evaluation Daughtercard The SX-560-6900 Eva

Strona 14 - Installing the SX-560 Module

Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc. www.silexamerica.com

Strona 15 - OEM Interface

Page 6 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 The Evaluation Daughtercard makes it easy to connect to the SX-560 f

Strona 16 - Electrical Characteristics

Installing the Evaluation Daughtercard Silex Page 7 Part Number 140-00192-100 Verify Development Kit Contents The SX-560-6900 Evaluation Module Dev

Strona 17 - Serial Ports

Page 8 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 Installing the SX-560 Module To install the SX-560 module in the SX-

Strona 18 - RS-232 Cable

Installing the Evaluation Daughtercard Silex Page 9 Part Number 140-00192-100 Monitoring Module Status You can monitor the module status using the

Strona 19 - Page 13

Page 10 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 Table 4 OEM Interface Signal Descriptions Signal Pin Type Descrip

Strona 20 - 26-Pin I/O Header

Installing the Evaluation Daughtercard Silex Page 11 Part Number 140-00192-100 Power Management The SX-560 power consumption is typically 280mA for

Strona 21 - Page 15

Page 12 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 DB-9 RS-232 Signal Type 7 RTS Output (not supported on Serial Port

Strona 22 - Serial Peripheral Interface

Installing the Evaluation Daughtercard Silex Page 13 Part Number 140-00192-100 Figure 5 RS-232 Cable Pinouts Table 7 RS-232 Cable Pinout Descript

Strona 23 - LCD Interface

Part Number 140-00192-100 Revision C-2 © 2008 Silex Technology America, Inc.. All rights reserved. October, 2008 Silex Technology America SPECIFI

Strona 24 - Page 18

Page 14 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 Figure 6 GPIO Special Functions Jumpers (Example Configur

Strona 25 - Configuring the SX-560

Installing the Evaluation Daughtercard Silex Page 15 Part Number 140-00192-100 As discussed in the previous section, GPIOs 3 through 8 are set by d

Strona 26 - Configuration Methods

Page 16 silex Installing the Evaluation Daughtercard Part Number 140-00192-100 USB Host Port and Ethernet Port The USB V1.1 host port, located on

Strona 27 - Page 21

Installing the Evaluation Daughtercard Silex Page 17 Part Number 140-00192-100 LCD Interface A 16x2 LCD display is available as an option for the SX

Strona 28 - Connection)

Page 18 silex Installing the Evaluation Daughtercard Part Number 140-00192-100

Strona 29

Configuring the SX-560 Silex Page 19 Part Number 140-00192-100 Chapter 3 Configuring the SX-560 This chapter describes the methods for config

Strona 30 - 140-00192-100

Page 20 Silex Using the SX-560 Part Number 140-00192-100 Serial Port Settings (must match the settings of the attached serial device): • Baud Rate

Strona 31 - Page 25

Configuring the SX-560 Silex Page 21 Part Number 140-00192-100 Initial Wireless Setup procedure described previously in this chapter, or the interna

Strona 32 - Page 26

Page 22 Silex Using the SX-560 Part Number 140-00192-100 Using the ExtendView Utility to Configure the SX-560 (Ethernet Connection) The ExtendV

Strona 33

Configuring the SX-560 Silex Page 23 Part Number 140-00192-100 3. Right-click on the SX-560 that you want to configure from the displayed list, an

Strona 34 - Page 28

Contents Silex Page i Part Number 140-00192-100 Contents About This Reference Guide...

Strona 35

Page 24 Silex Using the SX-560 Part Number 140-00192-100 6. Click the Wireless tab to configure the 802.11a/b/g wireless settings. To operate on

Strona 36 - Page 30

Configuring the SX-560 Silex Page 25 Part Number 140-00192-100 8. You do not need to change any of the settings in this window. Click the Serial

Strona 37 - Chapter 4

Page 26 Silex Using the SX-560 Part Number 140-00192-100 Using a Web Browser to Configure the SX-560 After you have entered an IP address into t

Strona 38 - Serial Port Emulator

Configuring the SX-560 Silex Page 27 Part Number 140-00192-100 If you used DHCP, verify that the IP address is correctly set. If you used the defa

Strona 39 - Raw TCP connection

Page 28 Silex Using the SX-560 Part Number 140-00192-100 5. Select the appropriate wireless encryption mode and enter the required settings (check

Strona 40 - ECable Mode

Configuring the SX-560 Silex Page 29 Part Number 140-00192-100 2. If you are connected to Serial Port 3, you will see some information about the fi

Strona 41 - Console Mode Switching

Page 30 Silex Using the SX-560 Part Number 140-00192-100 Configuring 802.1X EAP authentication can be complex. Please refer to Appendix A and/or

Strona 42 - AT Commands

Using the SX-560 Silex Page 31 Part Number 140-00192-100 Chapter 4 Using the SX-560 with Your Application The SX-560 includes a number of capabilit

Strona 43 - Chapter 5

Page 32 Silex Using the SX-560 Part Number 140-00192-100 defined code. For example, by changing the OEM code to XYZ, the default server name SDS000

Strona 44 - Interfacing the SX-560

Using the SX-560 Silex Page 33 Part Number 140-00192-100 After the Serial Port Emulator software has started, you will see a list of all the confi

Strona 45 - Page 39

Page ii Silex Contents Part Number 140-00192-100 SNMP Traps, Email Alerts, and GPIO Status ...

Strona 46

Page 34 Silex Using the SX-560 Part Number 140-00192-100 where ipaddress is the IP address of the SX-560 and portnumber is the SX-560 TCP port numbe

Strona 47 - SX-560 Power Requirements

Using the SX-560 Silex Page 35 Part Number 140-00192-100 6. It is also possible to use UDP instead of TCP for communicating to and from the SX-560.

Strona 48 - Antenna Connectors

Page 36 Silex Using the SX-560 Part Number 140-00192-100 Once you are connected in console mode, you can send any of the console commands listed in

Strona 49 - Retaining Bracket (Optional)

Interfacing the SX-560 Silex Page 37 Part Number 140-00192-100 Chapter 5 Interfacing the SX-560 to the OEM Device In order to connect the SX-560

Strona 50 - Page 44

Page 38 Silex Interfacing the SX-560 Part Number 140-00192-100 Figure 8 SX-560 Evaluation Daughtercard Schematics

Strona 51 - Advanced Configuration

Interfacing the SX-560 Silex Page 39 Part Number 140-00192-100 Figure 8a SX-560 Evaluation Daughtercard Schematics

Strona 52 - Modifying TCP/IP Settings

Page 40 Silex Interfacing the SX-560 Part Number 140-00192-100 OEM Interface The OEM Interface (JP2) is the primary method for communications betwe

Strona 53 - Page 47

Interfacing the SX-560 Silex Page 41 Part Number 140-00192-100 Signal Pin Type Description CTS1- 28 Input Serial Port 2 Clear to Send RXD1 34 Input

Strona 54 - Advanced Configuration

Page 42 Silex Interfacing the SX-560 Part Number 140-00192-100 Installing the SX-560 The spacers are installed with the SX-560-1701 WLAN model

Strona 55 - Configuring SNMP

Interfacing the SX-560 Silex Page 43 Part Number 140-00192-100 Table 15 Antenna Connector Types Parameter Description Connector Type SMT Ultra-min

Strona 56 - Page 50

Contents Silex Page iii Part Number 140-00192-100 Figures Figure 1 SX-560 top and bottom view ...

Strona 57 - Page 51

Page 44 Silex Interfacing the SX-560 Part Number 140-00192-100 Regulatory Approval Requirements The SX-560 has FCC and IC Modular Approval. This al

Strona 58

Advanced Configuration Silex Page 45 Part Number 140-00192-100 Chapter 6 Advanced Configuration The SX-560 module is equipped with a default conf

Strona 59 - Page 53

Page 46 Silex Advanced Configuration Part Number 140-00192-100 Parameter Description Settings Default Setting Econn ECable connection attempt ti

Strona 60 - Page 54

Advanced Configuration Silex Page 47 Part Number 140-00192-100 2. Verify the settings, as defined in Table 18. Table 18 TCP/IP Settings Parameter

Strona 61 - Page 55

Page 48 Silex Advanced Configuration Part Number 140-00192-100 Figure 14 Advanced TCP/IP Configuration Window 5. Configure the settings, as

Strona 62 - Page 56

Advanced Configuration Silex Page 49 Part Number 140-00192-100 Configuring SNMP The SX-560 module contains a Simple Network Management Protocol (SNM

Strona 63 - Page 57

Page 50 Silex Advanced Configuration Part Number 140-00192-100 Figure 15 SNMP Configuration 2. Click the Submit button to save the changes.

Strona 64 - Page 58

Advanced Configuration Silex Page 51 Part Number 140-00192-100 Table 21 GPIO General Commands Command Description SET GPIO DIR [IN|OUT] <gpio-nu

Strona 65 - Page 59

Page 52 Silex Advanced Configuration Part Number 140-00192-100 SET GPIO DIRM <bit-mask> GPIO # = {1|2|3|4|5|6|7|8} Sets all directio

Strona 66

Advanced Configuration Silex Page 53 Part Number 140-00192-100 Example: Local> show gpio special GPIO Special Functions -----------------------

Strona 67 - ------

Page iv Silex Contents Part Number 140-00192-100 Table 36 Server Information Commands ...

Strona 68 - Using AT Modem Commands

Page 54 Silex Advanced Configuration Part Number 140-00192-100 Table 22 GPIO Trigger Commands Command Description SET GPIO TRIGger [1 | 0| DIS]

Strona 69 - Page 63

Advanced Configuration Silex Page 55 Part Number 140-00192-100 Command Description SET GPIO TRIGM <bit-mask> Sets all trigger control bi

Strona 70 - Page 64

Page 56 Silex Advanced Configuration Part Number 140-00192-100 Table 23 GPIO Transmit Commands Command Description SET GPIO TRANsmit <trig

Strona 71 - Response Codes

Advanced Configuration Silex Page 57 Part Number 140-00192-100 Command Description SET GPIO DATA <bit-mask> Sets all the data out control bit

Strona 72 - Page 66

Page 58 Silex Advanced Configuration Part Number 140-00192-100 Table 25 E-GPIO TCP Monitor Commands The E-GPIO TCP monitor allows a computer s

Strona 73 - Product Specifications

Advanced Configuration Silex Page 59 Part Number 140-00192-100 GPIO set message format This message may be optionally sent by the remote compu

Strona 74 - TCP Port Connections

Page 60 Silex Advanced Configuration Part Number 140-00192-100 GPIO direction control Integer read-only gpio.2 This is an integer represen

Strona 75 - Appendix A

Advanced Configuration Silex Page 61 Part Number 140-00192-100 Configuring Serial Port Monitor Alert and Trap Configuration The SX-560 module can be

Strona 76 - Page 70

Page 62 Silex Advanced Configuration Part Number 140-00192-100 Setting up Email Alerts and SNMP Traps After you have created the GPIO and/or Ser

Strona 77 - Page 71

Advanced Configuration Silex Page 63 Part Number 140-00192-100 Standard AT Commands Supported The following standard AT commands are interpreted by

Strona 78 - Page 72

About This Reference Guide Silex Page 1 Part Number 140-00192-100 About This Reference Guide This reference guide provides detailed specifications,

Strona 79 - Appendix B

Page 64 Silex Advanced Configuration Part Number 140-00192-100 Parameter Command Description Echo control ATEn If n=0, commands are not echoed.

Strona 80 - Page 74

Advanced Configuration Silex Page 65 Part Number 140-00192-100 Response Codes Table 30 details the response codes for codes other than #C commands.

Strona 81 - Page 75

Page 66 Silex Advanced Configuration Part Number 140-00192-100

Strona 82 - Page 76

Product Specifications Silex Page 67 Part Number 140-00192-100 Chapter 7 Product Specifications Table 31 Product Specifications Component Specific

Strona 83 - Page 77

Page 68 Silex Product Specifications Part Number 140-00192-100 Parameter Specifications Channel Number IEEE 802.11b and g: Channels 1 to 11 and 12 to

Strona 84 - Port Commands

Advanced Security Configuration Silex Page 69 Part Number 140-00192-100 Appendix A Advanced Security Configuration There are numerous possible secur

Strona 85 - Server Information Commands

Page 70 Silex Advanced Security Configuration Part Number 140-00192-100 Encryption Mode The possible SX-560 wireless encryption modes include: • 6

Strona 86 - Page 80

Advanced Security Configuration Silex Page 71 Part Number 140-00192-100 Realm A realm defines a grouping of users. If a realm is required for your ne

Strona 87 - Service Commands

Page 72 Silex Advanced Security Configuration Part Number 140-00192-100

Strona 88 - Page 82

Console Commands Silex Page 73 Part Number 140-00192-100 Appendix B Console Commands The following tables describe the console commands available fr

Strona 89 - SNMP Commands

Page 2 Silex About This Reference Guide Part Number 140-00192-100

Strona 90 - String Commands

Page 74 Silex Console Commands Part Number 140-00192-100 Command Description SET NW AUTHtype Sets wireless authentication type The default value is O

Strona 91 - TCP/IP Commands

Console Commands Silex Page 75 Part Number 140-00192-100 Command Description SET NW MOde Sets WLAN mode The possible modes are Infrastructure and Ad-

Strona 92 - Page 86

Page 76 Silex Console Commands Part Number 140-00192-100 Command Description SH NW STATS Shows network I/O statistics Sample output: WiFi statistics:

Strona 93 - Page 87

Console Commands Silex Page 77 Part Number 140-00192-100 Command Description SET NW INAP Sets EAP inner-authentication protocol The possible protocol

Strona 94 - Page 88

Page 78 Silex Console Commands Part Number 140-00192-100 Command Description SET NW WPAPSK Sets WPA PSK pass phrase or hex key. This value is only

Strona 95 - Power Configuration Commands

Console Commands Silex Page 79 Part Number 140-00192-100 Command Description CLEAR PORT S1 JOB Aborts the active job on the port. If the remote hos

Strona 96 - Help Commands

Page 80 Silex Console Commands Part Number 140-00192-100 Command Description SH SERIAL Displays serial number of the unit Sample output: Serial numbe

Strona 97 - Appendix C

Console Commands Silex Page 81 Part Number 140-00192-100 Service Commands Table 37 Service Commands Command Description SET SERVI <service name&g

Strona 98 - Page 92

Page 82 Silex Console Commands Part Number 140-00192-100 Command Description SET SERVI <service name> FMS Sets filter 1 text replacement match

Strona 99 - Part Number 40183-101

Console Commands Silex Page 83 Part Number 140-00192-100 Command Description SET SERVI <service name> TCP Sets raw TCP port for service If por

Strona 100 - Engineering Drawings

Introduction Silex Page 3 Part Number 140-00192-100 Chapter 1: Introduction The SX-560 embedded intelligent module provides a complete solution for

Strona 101 - Firmware Update Procedures

Page 84 Silex Console Commands Part Number 140-00192-100 SET SNMP LOCation Sets system location string The default value is null. Format: SET SNMP LO

Strona 102 - Page 96

Console Commands Silex Page 85 Part Number 140-00192-100 Command Description # Filter 0 No Filter 1 Text Substitution 2 AppleTalk

Strona 103 - Appendix E

Page 86 Silex Console Commands Part Number 140-00192-100 Command Description Format: SET IP FTIme [ENable | DIsable] SET IP FTP Enables or disable

Strona 104 - SVL USB Firmware

Console Commands Silex Page 87 Part Number 140-00192-100 Command Description SET IP TCP [ENable | DIsable] SET IP TELnet Enables or disables Telne

Strona 105 - Appendix F

Page 88 Silex Console Commands Part Number 140-00192-100 Command Description SH IP Shows TCP/IP related parameters Sample Output: IP is enabled IP ad

Strona 106 - GNU/Linux Programming

Console Commands Silex Page 89 Part Number 140-00192-100 Command Description 19 00080000 GPIO Trigger4: GPIO4 0 to 1 20 00100000 GPIO Trigger5: G

Strona 107 - Silex Contact Information

Page 90 Silex Console Commands Part Number 140-00192-100 Miscellaneous Commands Table 42 Miscellaneous Commands Command Description SET DEFAULT Set

Strona 108 - Page 102

Engineering Drawings Silex Page 91 Part Number 40183-101 Appendix C Engineering Drawings Antenna Cable Drawings and Specifications Figure 16 Ante

Strona 109

Page 92 Silex Engineering Drawings Part Number 140-00192-100 Table 43 Electrical Performance Parameter Value Impedance 50 ohms Frequency Range 1 to

Strona 110

Engineering Drawings Silex Page 93 Part Number 40183-101 Table 44 Electrical Specifications Parameter Value Antenna Type Dipole Swivel Antenna Frequ

Komentarze do niniejszej Instrukcji